SK200 003 Energy Management System Kit (Motion) for PECO

RRP:
$119.24
Your Price:
$67.71 (You save $51.53)
Availability:
in stock
Quantity:

Bookmark and Share


Product Description

occupancy.png

 

 

Click here for a PDF with manuals and spec sheets for PECO Occupancy Sensors and Accessories

 

The SK200-003 Energy Management Kit is an occupancy sensing addition to compatible PECO thermostats.

Included in this system:

SB200-001

Motion Sensor : The SB200-001 is an occupancy sensor designed for automatic HVAC system control. This sensor provides changeover relay signal output for a PECO thermostat to activate/deactivate an HVAC system. This sensor can be wall or corner mounted with 110 degree, 50 ft (15m) detection range.

SE200-001 Door Switch: To be recess mounted on the frame of entry door. It will report open/closed status of the door. Once the door is opened, the system will enter into a "standby" mode while attempting to detect human presence. If motion is detected, the SD200-001 (Master Sensor & Controller) will verify the room as "occupied," and allow for the HVAC unit to operate.

 

So, how does this work?

  1. If the room is vacant, the system will be in Standby Mode. The HVAC system does not operate in this mode.
    *While in Standby Mode, the thermostat measures the room temperature every 5-minutes. When the room temperature becomes higer or lower than the high/low temperature limit settings, the HVAC unit will automatically operate until the room temperature is back within range. 
  2. If any sensors installed detect movement during Standby Mode, the system will enter into Occupied Mode. In Occupied Mode, the user can operate the HVAC system.
  3.  Whenver the door is opened, the system will detect it and enter into Door-Open Mode. If the door is left open for more than 5 minutes, the system will shut off the HVAC unit until the door is closed.
  4. Once the door is closed, the system will enter into Delay Mode. During this 10 second period, the system will remain in it's original mode.
  5. After the 10 second delay, the system will enter into Waiting Mode. If any of the sensors detect movement during Waiting Mode, the system will enter into Occupied Mode. If no movement is detected within 5 minutes, the system will revert to Standby Mode, shutting off the HVAC unit.

See below for Operation Diagram

 

SB200-001 Details

sb200-jumpers.png

 

 

SB200-001 Operation Diagram
sb200-operation.png